@ Signal Generators- 10 to 7,600 mc
-hp- 618A SHF SIGNAL GENERATOR
i
3,800 to 7,600mc.Provides a 1 m w signal into a 50-ohm coaxial load (zero dbm). Output attenuator directly calibrated in dbm and volts, reduces output level to less than -100 dbm. Frequency dial directly calibrated, accuracy % of 1 %. Repellor voltage automatically tracked. No adjustment during operation. CW, pulsed and FM output. $2,250.00
1
1
~
I
-hp- 608A
1
4
~
i
,o to 5oo mc
.hp6108
Calibrated output, 1 v to 1 pv Internal 450 to 1,200 mC pulse modulation Direct calibration - - - .1 -.~
___-__
+-
Output 1 v to 1 pv Amplitude modulated, pulsed and CW output Direct reading _ _ _ _ --
_,
I
$85000 -. _ ___.
__
1 A
'
,
?
__
1
$925 00
--I
- h P 61 4A
1
~
8oo to 2,100 mc
-
,
-
Direct reading Pulse modulation, CW 8 FM Output 1 m w o r 2 2 3 v t o 1 pv
_ i _
$1,950 00
_. .
i1
-- h p 61 6A
-
-
I
__
,
___._
- -*
i
r
.__
-*1
1.800 to 4,000 mc 3,800 lo 7,600 mc
Direct reading Pulse modulation, CW 8 FM Output 1 or 223 v to 1
mw
pv _.
$1,950 00
'
-hp. 618A
Direct reading. External pulse modulation, C W 8 FM Output 223 Y to 2 23 pv
$2,250 00
@ Distortion, Wave Form Analyzers-20 cps to 20 kc
-hp-
330B DISTORTION ANALYZER
Analyzer -hp- 300A - h p 320A -hp. 3208 -hp- 3308 -hp. 330C
Primary US S . Wave form analyzer Measures total distortion Measures total distortion Measures total distortion
For FM
measurements
Frequency Range 30 cpr to 16 kc 400 cps and 5 kc 50, 100, 400 cps, 1, 5 and 7.5 kc 20 cps to 20 kc 20 cps to 20 kc 20 cps to 20 kc
Characteristics Variable selectivity; measuring range 1 mv to 500 v. Requires external detectoi Same as above Includes input amplifier, VTVM Special C . meter to meet C . VU F. requirements AM detector and VU meter to F. meet C. C. requirements Output 50 v. peak-to-peak.
Pric. $625.00 $ 75.00
Measures distortions as low as 0.1 % at any fre uencv, 20 cps to 20 Measures noise voltages as low as 100 pv. High sensitivity, high stability, broad applicability for broadcast, laboratory or production prob1ems.Wide band 20 db gain input amplifier. Burltin vacuum tube voltmeter usable separately. $395.00
IC.
$1 50.00
$395.00 $425.00
FM, AM-FM MODELS
-bp- 330C, for FM broadcasters, includes VU meter meeting F. C. C. requirements. -bp- 3 3 0 0 , for AMFM broadcasters. includes AM detector to rectifv AM carrier, plus VU meter employed in modi1 330C. 330C, $425.00. 330D, $440.00
- h p 330D
Far AM. FM measurementi
$440.00
SQUARE W A V E GENERATOR
- h p 2lOA
Transient and frequency response 20 cps to 10 kc
1,000 ohm impedance
$1 50.00
,
@
Frequency Measuring Equipment -.01 cps to 10 mc
- h p - 524A FREQUENCY COUNTER Instantly, automatically, directly measures
Instrurnmnt Primary US S . Frequency Range Characteristics Direct reading, no Interpolation, accuracy about 2/1,000,000 Stability 1/1,000,000 Ishort-time1 Sine or rectangular output Marker paps Accurote within i ,001 ' . Sine /, woves only. Pric. $2,000 00
unknown frequencies, 0.01 cps t o 1 0 m c ! O n e instrument combines functiom of frequency standard, interpcilating system and detector! Amazingly simple operation -just connect unknown t o input terminal, and exact frequency appears automatically o n front panel. High speed decade scalers count unknown
F ~ q ~ ~ ~ cFrequency, interval, ",
Counte~
t i m e measurements
01 cps'o 10 mc
100 kc, 10 kc, 1 kc, 100 cps, 10 cps
;$;:,",9",
Standord
Frequency, time measurements Audio, supersonic calibration
$ 6oo
O0
zo::::
Standard -hpFrequency Meter -hp- 505A Tachometer -hp- 5058 ~~~h~~~~~~
100 kc, 10 kc, 1 kc, 100 cps
cps to
$ 450.00
frequency over measured, crystal-controlled time interval. Accuracy of measurement f l count f crystal stability (2/1,000,000 er week). External higher accuracy standard usaile if desired. Minimum of unknown, 1 v peak. $2,000.00
Rapid frequency measurements
Of
kc
10 ranger I % accuracy. Input 2 0.5 to 200 volts.
10 ranges t 2 % accuracy.
$ 210.00
mochinery Same as above
300 to 3,000,000 rpm
$ 300.00
-hp-
1000 SECONDARY FREQUENCY STANDARD
5 to 50,000 rps
Same
in except calibrated rps.
$ 300.00
Swift, sure frequency comparison, new convenience in standardizing with minimum external equipment. 100 Ltsec time markers. built-in oscilloscoDe. sine or rectangular waves. Low output impedance, shorttime stability 1/1,000,000. Performs most functions of expensive primary standards in audio, rf or supersonic ranges. $600.00
1 ,
Frequency monitors available for FM broadcast, 88 to 108 mc, TV aural broad. 59.75 to 215.75 mc; and for communications systems, 30 to 175 mc. cast
5
Data Subject to Change Without Notice. Prices f: 0. b. Factory.
..
.
I
TT-PACKAR'D